M-HC-012

Key features:

 

Pressure on demand

Solenoid activated

High pressure – up to 700 bar (10,000 psi)

Max. inlet pressure = 350 bar (5,000 psi)

Fast fill – system flows up to 400 l/min

Adjustable outlet pressure

Extended service life

Robust design

Flexible design; several boosters/intensification factors

 

 

 

Description

The M-HC-012 In-line Intensifier System is designed to boost the hydraulic pressure from the pump to the workload. The system operates by solenoid activation. The operator is in full control of the system and can decide if a boosted pressure to the workload should be applied.

The system is dynamical by means of being able to provide flow at high pressure for intermittent use (< 10 min duty cycle).

Typical applications

Mobile attachments; motors – steering systems – cutters – crushers – shears, off highway equipment, injection molding machines and hydraulic presses. Applicable to machines with insufficient pump capacity to prevent machine stoppage when peak pressures occur.

Easy installation

M-HC-012 is provided with four mounting holes for through bolt installation. The four connection ports are placed logically in pairs and in line of each other on the HIC block. All surfaces are electroplated for good protection and fine surface finish.

Functions

The function of the system is simple, but smart. The system operates by solenoid activation. The operator is in full control of the system and can decide if a boosted pressure to the workload should be applied.

A relief valve is installed to control the maximum allowable pressure that the system can output, and allowing the booster to go for a higher end pressure producing flow at the decided pressure.

Function diagram

012-01

Connection types

ConnectionP / T / Z / HM (P / H / 1), F1 / F2
M-HC2D-01_-1L551/2" BSPP1/4" BSPP
M-HC2D-01_-1L1001/2" BSPP1/4" BSPP
M-HC3-01_-1L551/2" BSPP1/4" BSPP
M-HC3-01_-1L1001/2" BSPP1/4" BSPP
M-HC6D-01_-1L551/2" BSPP1/4" BSPP
M-HC6D-01_-1L1001/2" BSPP1/4" BSPP
M-HC6D-01_-1L2001 1/4" BSPP1/4" BSPP
M-HC6D-01_-1L4001 1/4" BSPP1/4" BSPP

Flange mounting

Flange mounting drawing HV-399-02

Fluids and materials

Additional information is available on the website under Products → General specifications.

Ordering an M-HC-012

Ordering example of an M-HC-012 for 700 bar, connection tube BSPP with HC3 i = 3.2, static use:

M-HC3-012-1L100 mounted with HC3-3.2-A-D

Guidance to calculate the intensification factor for dynamic or static use is at the bottom of this section.

Attention note!
Valve pre-settings are required, please specify when ordering the intensifier system.
M-HC-012 is as standard mounted with 12VDC coil. Other voltage available on request.

Selection of intensifier system

Ordering codeConnectionBypass flowMax. pressureWeightDimension drawing PDF
M-HC2D-012-1L55 Tube55 l/min700 bar12.4 kgM-HC2D-012-1L55-02
M-HC3-012-1L55 Tube55 l/min700 bar10.8 kgM-HC3-012-1L55-02
M-HC2D-012-1L100Tube100 l/min700 bar12.6 kgM-HC2D-012-1L100-00
M-HC3-012-1L100Tube100 l/min700 bar11.0 kgM-HC3-012-1L100
M-HC6D-012-1L100Tube100 l/min700 bar33.0 kgM-HC6D-012-1L100
M-HC6D-012-1L200Tube200 l/min700 bar44.0 kgM-HC6D-012-1L200-00
M-HC6D-012-1L400Tube400 l/min700 bar47.0 kgM-HC6D-012-1L400-01
M-HC2D-012-FK100Flange100 l/min500 bar10.5 kgM-HC2D-012-FK100-01
M-HC3-012-FK100Flange100 l/min500 bar10.8 kgM-HC3-012-FK100-01
M-HC3-012-FL55 Flange55 l/min700 bar10.8 kgM-HC3-012-FL55-01
M-HC2D-012-FL100Flange100 l/min700 bar11.5 kgM-HC2D-012-FL100-00
M-HC3-012-FL100Flange100 l/min700 bar9.8 kgM-HC3-012-FL100-01
M-HC6D-012-FL100Flange100 l/min700 bar30.0 kgM-HC6D-012-FL100
M-HC6D-012-FL200Flange200 l/min700 bar40.0 kgM-HC6D-012-FL200-00
M-HC6D-012-FL400Flange400 l/min700 bar43.0 kgM-HC6D-012-FL400

Selection of intensification factor

HC2D-_._-A-DHC3-_._-A-DHC6D-_._-A-D
1.61.51.5
1.92.02.0
2.22.82.5
2.63.23.3
3.24.04.0
4.05.04.9
5.06.66.3
6.69.08.2
9.0

The intensification factor depends on available inlet and desired outlet pressure. To calculate the initial factor, use the following formular:

i = Desired high pressure / pump pressure

Desired pressure: 550 bar
Pump pressure: 207 bar
i = 550 / 207 = 2.7

For static use: Select an intensification factor higher or equal to the calculated value. In this example calculated i = 2.7, select factor i = 2.8 for an HC3 booster. The desired pressure of 550 bar is finally adjusted with the Pressure Reducing Valve (5).

For dynamic use: Select an intensification factor 40% higher than the calculated value. In this example calculated i = 550 / 207 = 2.66 + 40% = 3.7, select factor i = 4.0 for an HC3 booster. The desired pressure of 550 bar is finally adjusted with the Relief Valve (6).

Max. tightening torque BSPP

P / TH / Z
1/2" BSPP1/2" BSPP
with steel washer13.0 da/Nm13.0 da/Nm
with cutting edge13.0 da/Nm13.0 da/Nm