M-HC7-DA
Data:
Portable and easy to operate
Reliable and simple performance
Flexible design; several intensification factors
Output pressure in both directions
Multiple connection possibilities
Extended service life
Robust design
PIN: 20 – 350 bar
PH: Up to 2,000 bar maximum
Q: Up to 40 l/min
Weight: 14.0 kg.
Description
The miniBOOSTER Portable Intensifier System M-HC7-DA is a rugged unit designed for demanding industrial applications. The M-HC7-DA can be used with any low-pressure, from 20 to 350 bar, and with a power source that provides a minimum flow of 2 l/min. Output pressure as high as 1,000 bar in both directions.
Reliability is a primary design consideration. The M-HC7-DA is equipped with a 12-micron filter and a visual filter condition indicator. Service life is extended and down-time avoided.
Portability and ease of operation
With a weight of only 14 kg and a convenient lifting handle, the M-HC7-DA can be easily carried to where it is needed. The M-HC7-DA operates from an existing low-pressure hydraulic supply. No additional utilities are required. All controls are incorporated into the unit and provide simple and reliable performance.
Time is money: The M-HC7-DA can deliver up to 40 l/min and is designed to ensure that system capacity is directed to your process until intensification is required. Cycle times are minimised. Many applications require that the unit provide exceptional accuracy. The M-HC7-DA is proven with two easy-to-read 4” diameter pressure gauges to permit accuracy to be controlled within a tolerance of 1%.
Function diagram M-HC7-DA
System with 2 off pressure-reducing valves
Connection types
Connection | P / P1 / M1 / M2 / Z | T | Ha / Hb |
---|---|---|---|
M-HC7-812A-1___DA | 1/4" BSPP | 3/8" BSPP | 1/4" BSPP - 120° cone |
Fluids and materials
Additional information is available on the website under Products → General specifications.
Ordering an M-HC7-DA
Ordering example of an intensifier system M-HC7-DA for 1,000 bar with two (2) pressure-reducing valves, mounted with an HC7-FF with i = 7.6, DV incorporated and BSPP connections.
M-HC7-812A-1N02DA mounted with HC7 – 7.6 – B – FF
Attention notes!
Valve pre-settings are required. Please specify when ordering the intensifier system.
Selection of intensifier system
Ordering code | Connection | Max. pressure | Weight | Function diagram | Dimension drawing PDF |
---|---|---|---|---|---|
M-HC7-812A-1N02DA | Tube | 1,000 bar | 14 kg | 07-812A-1N02DA-00 | M-HC7-812A-1N02DA-00 |
M-HC7-812A-1O02DA | Tube | 1,500 bar | 14 kg | 07-812A-1O02DA-00 | M-HC7-812A-1O02DA-00 |
M-HC7-812A-1P02DA | Tube | 2,000 bar | 14 kg | 07-812A-1P02DA-00 | M-HC7-812A-1P02DA-00 |
Selection of HC7-FF intensification factor
Model | Intensification, i | Model version | Connection |
---|---|---|---|
HC7 | 4.0 | B | FF |
HC7 | 5.0 | B | FF |
HC7 | 6.6 | B | FF |
HC7 | 7.6 | B | FF |
HC7 | 9.0 | B | FF |
HC7 | 10.3 | B | FF |
HC7 | 13.0 | B | FF |
HC7 | 16.0 | B | FF |
HC7 | 20.0 | B | FF |
HC7 | 25.0 | B | FF |