HC2-F

Data:

 

HC2-F versions: 15 different intensification factors

PIN: 20–207 bar

PH: 800 bar maximum

PRETURN: As low as possible (return pressure to tank)

POUTLET: PH = (PIN – PRETURN) i (intensification)

Mounting: Flange, manifold system miniBOOSTER pattern

Weight: 1.2 kg.

 

Model versions:

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

Material certificate 3.1 on request

Description

The HC2-F is a variant of the HC2 for flange mounting on the low pressure side. The entire pattern is a miniBOOSTER design. It is a compact unit weighing only 1.2 kg. It is ideal for use in a variety of applications where building and maintaining high pressure is required.

The HC2-F raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure.

Flow rates

Intensification factor
i
Max. intensified outlet flow
l/min
Max. inlet flow
l/min
1.23.58.0
1.54.212.0
2.03.212.0
2.22.912.0
2.52.713.0
2.82.513.0
3.22.515.0
4.02.014.0
5.01.614.0
6.61.313.0
9.00.913.0
13.00.612.0
16.00.512.0
20.00.312.0
25.00.212.0

Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high-pressure side H. In this condition maximum flow through the booster is achieved giving a fast-forward function.

When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

Function diagram

2-105-01

Dimensions

Dimension drawing 2-135-01

Connection types

ConnectionIN / RH
1FFlange1/4" BSPP
2FFlange9/16-18 UNF

Fluids and materials

Additional information is available on the website under Products → General specifications.

Ordering an HC2-F

Ordering example of an HC2-F with i = 4.0 DV incorporated and BSPP connection on the H-port: HC2 – 4.0 – B – 1F

Attention note!
The G-model is available in 2 variants, when ordering please specify accordingly:

  • Dynamic – low hysteresis: Ordering example of an HC2-F with i = 4.0 RV incorporated and BSPP connection on the H-Port: HC2 – 4.0 – G – 1F
  • Fail safe – high hysteresis: The RV valve opening ratio is to be determined on individual basis. Contact our technical support. Ordering example of an HC2-F with i = 4.0 RV with opening ratio x.x incorporated and BSPP connection on the H-port: HC2 – 4.0 – G – x.x – 1F
R

Model

  • HC2
R

Intensification, i

  • Select factor
  • See flow rate table
R

Model version

  • Select type
  • A = without DV
  • B = with DV
  • G = with proportional valve
R

Connections

  • Select thread
  • 1F = BSPP H-port
  • 2F = UNF H-port

Max. tightening torque BSPP

IN / RH
Flange1/4" BSPP
with steel washer4.0 da/Nm
with cutting edge4.0 da/Nm

Max. tightening torque UNF

IN / RH
Flange9/16-18 UNF
with o-ring3.5 da/Nm