HC6
Data:
HC6 versions: 9 different intensification factors
PIN: 20 – 207 bar
PH: 800 bar maximum
PRETURN: As low as possible (return pressure to tank)
POUTLET: PH = (PIN – PRETURN) i (intensification)
Mounting: Inline tube
Weight: 9.5 kg.
Description
The HC6 is a high-flow unit which is capable of delivering up to 28.3 l/min flow on the high-pressure end.
Like other miniBOOSTER models, the HC6 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC6 is a compact unit weighing only 9.5 kg.
Flow rates
Intensification factor i | Max. intensified outlet flow l/min | Max. inlet flow l/min |
---|---|---|
1.3 | 20.3 | 50.0 |
1.5 | 28.3 | 80.0 |
1.9 | 22.3 | 80.0 |
2.5 | 17.0 | 80.0 |
3.3 | 12.8 | 80.0 |
4.0 | 10.6 | 80.0 |
4.9 | 8.6 | 80.0 |
6.3 | 6.7 | 80.0 |
8.2 | 5.2 | 80.0 |
Functions
The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high-pressure side H. In this condition maximum flow through the booster is achieved giving a fast-forward function.
When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.
Function diagram
6-105-01
Dimensions
Dimension drawing 6-120-04
Connection types
Connection | IN / R | H |
---|---|---|
1 | 1/2" BSPP | 1/2" BSPP |
Fluids and materials
Additional information is available on the website under Products → General specifications.
Ordering an HC6
Ordering example of an HC6 with i = 4.0, DV incorporated and BSPP connections: HC6 – 4.0 – B – 1
Attention note!
The G-model is available in 2 variants, when ordering please specify accordingly:
- Dynamic – low hysteresis: Ordering example of an HC6 with i = 4.0 RV incorporated and BSPP connections: HC6 – 4.0 – G – 1
- Fail safe – high hysteresis: The RV valve opening ratio is to be determined on individual basis. Contact our technical support. Ordering example of an HC6 with i = 4.0 RV with opening ratio x.x incorporated and BSPP connections: HC6 – 4.0 – G – x.x – 1
Model
- HC6
Intensification, i
- Select factor
- See flow rate table
Model version
- Select type
- A = without DV
- B = with DV
- G = with proportional valve
Connections
- Select thread
- 1 = BSPP
Max. tightening torque BSPP
IN / R | H | |
---|---|---|
1/2" BSPP | 1/2" BSPP | |
with steel washer | 13.0 da/Nm | 13.0 da/Nm |
with cutting edge | 13.0 da/Nm | 13.0 da/Nm |