HC9
Data:
HC9 version: 8 intensification factor
PIN: 20 – 207 bar
PH: 5,000 bar maximum
PRETURN: As low as possible (return pressure to tank)
POUTLET: PH = (PIN – PRETURN) I (intensification)
Mounting: Inline tube
Weight: 9.9 kg.
Description
The HC9 is an ultra high-pressure unit which is capable of delivering up to 5,000 bar and 0.4 l/min flow on the high-pressure end. Like other miniBOOSTER models, the HC9 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure.
Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC9 is a compact unit weighing only 9.9 kg.
Flow rates
Intensification factor i | Max. intensified outlet flow l/min | Max. inlet flow l/min |
---|---|---|
6.2 | 1.7 | 20.0 |
8.2 | 1.3 | 20.0 |
9.5 | 1.1 | 20.0 |
11.0 | 1.0 | 20.0 |
13.0 | 0.8 | 20.0 |
16.0 | 0.7 | 20.0 |
20.0 | 0.5 | 20.0 |
25.0 | 0.4 | 20.0 |
Functions
The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1 and KV2 to the high-pressure side H. In this condition maximum flow through the booster is achieved giving a fast-forward function.
When pump pressure is reached on the high-pressure side H, valves KV1 and KV2 will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.
Function diagram A-model
9-105-02
Function diagram B-model
9-106-00
Dimensions
Dimension drawing 9-120-13
Connection types
Connection | IN / R |
---|---|
1 | 1/2" BSPP |
High-pressure plate
High-pressure plate ordering code and specifications are show in the PDF-file: 8-900-14
Fluids and materials
Additional information is available on the website under Products → General specifications.
Ordering an HC9
Ordering example of an HC9 with i = 25.0, without DV and BSPP connections, mounted with high-pressure plate with HP-connection 1/4″ BSPP, PG-connection 9/16-18 UNF:
HC9 – 25.0 – A – 1 with 8-285
Attention note!
High-pressure plate is required, please specify ordering code – see high-pressure plate table.
High-pressure plate will be factory mounted.
Model
- HC9
Intensification, i
- Select factor
- See flow rate table
Model version
- Select type
- A = without DV
- B = with DV, up to 3000 bar
Connections
- Your selection
- 1
Max. tightening torque BSPP
IN / R | |
---|---|
1/2" BSPP | |
with steel washer | 13.0 da/Nm |
with cutting edge | 13.0 da/Nm |